PET is Wonderful Annual Meeting 2020 Oct 27, 2020 02:00 PM - 05:40 PM — Virtual Meeting (online)
Through the Looking Glass: Breaking Barriers in STEM Oct 28, 2020 12:00 PM - 03:30 PM — Virtual Meeting (online)
NRS Mental Health Network Annual Scientific Meeting 2020 Nov 04, 2020 09:00 AM - 05:30 PM — Virtual Meeting (online)
Scottish Radiological Society Annual General Meeting 2020 Nov 06, 2020 09:30 AM - 03:30 PM — Virtual Meeting (online)
IPEM educational meeting: Artificial Intelligence in MRI Nov 18, 2020 12:00 AM — Virtual Meeting (online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

The accuracy of pharmacokinetic parameter measurement in DCE-MRI of the breast at 3 T

Author(s): P. Di Giovanni, C. A. Azlan, T. S. Ahearn, S. I. Semple, F. J. Gilbert, T. W. Redpath

Abstract:
The purpose of this work is to quantify the accuracy of pharmacokinetic parameter measurement in DCE-MRI of breast cancer at 3 T in relation to three sources of error. Individually, T1 measurement error, temporal resolution and transmitted RF field inhomogeneity are considered. Dynamic contrast enhancement curves were simulated using standard acquisition parameters of a DCE-MRI protocol. Errors on pre-contrast T1 due to incorrect RF spoiling were considered. Flip angle errors were measured and introduced into the fitting routine, and temporal resolution was also varied. The error in fitted pharmacokinetic parameters, K-trans and v(e), was calculated. Flip angles were found to be reduced by up to 55% of the expected value. The resultant errors in our range of K-trans and v(e) were found to be up to 66% and 74%, respectively. Incorrect T1 estimation results in K-trans and v(e) errors up to 531% and 233%, respectively. When the temporal resolution is reduced from 10 to 70 s K-trans drops by up to 48%, while v(e) shows negligible variation. In combination, uncertainties in tissue T1 map and applied flip angle were shown to contribute to errors of up to 88% in K-trans and 73% in v(e). These results demonstrate the importance of high temporal resolution, accurate T1 measurement and good B1 homogeneity.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0031-9155
Publication Year: 2010
Periodical: Physics in Medicine and Biology
Periodical Number: 1
Volume: 55
Pages: 121-132
Author Address: