SINAPSE Virtual Happy Hour May 19, 2021 04:30 PM - 05:30 PM — Virtual Happy Hour (online)
9th Annual Scottish Radiotherapy Research Forum Jun 03, 2021 12:30 PM - 05:00 PM — Virtual Meeting (online)
Scottish Dementia Research Consortium Annual Conference 2021 Jun 16, 2021 10:00 AM - 03:30 PM — Virtual Meeting (online)
Medical Imaging Convention [rescheduled] Sep 15, 2021 - Sep 16, 2021 — National Exhibition Centre, Birmingham, England
2021 SINAPSE ASM Sep 16, 2021 - Sep 17, 2021 — Technology & Innovation Centre, University of Strathclyde, 99 George Street, Glasgow

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

AngioCT in the management of neurointerventional patients: a prospective, consecutive series with associated dosimetry and resolution data

Author(s): P. M. White, J. N. Gilmour, N. W. Weir, B. Innes, R. J. Sellar

Abstract:
Introduction Endovascular coiling of intracranial aneurysms carries a risk of complications. Early detection and management of complications can improve clinical outcomes. AngioCT is a new imaging technology enabling CT-like images to be generated on a flat-panel digital subtraction angiography system, which can provide immediate "on angio table" identification and thorough assessment of such complications. We prospectively audited its utility during aneurysm coiling in patients following subarachnoid haemorrhage (SAH). Methods A prospective series of 44 patients with SAH undergoing endovascular coiling with AngioCT was audited for image quality and the influence of the AngioCT on patient management. In a parallel experimental study, radiation doses were measured and image quality parameters on standard phantoms were established. Results In all patients, AngioCT provided adequate diagnostic information. In 40.9% of patients, AngioCT was a substantial or major factor in determining the management immediately after coiling. Using a 10-s high-dose acquisition technique, acceptable image quality could be obtained rapidly with a radiation dose just over half that for a conventional CT scan of the head (35 mGy versus approximately 60 mGy). No patient in this series required conventional CT to clarify the AngioCT appearance. Conclusion AngioCT has many applications in the neurointerventional setting. In particular during coiling, AngioCT provides a rapid way to clarify concerns or identify complications and in some cases was the major factor influencing further patient management immediately after coiling. AngioCT images were judged of adequate quality to be clinically useful in all patients in this series.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0028-3940
Publication Year: 2008
Periodical: Neuroradiology
Periodical Number: 4
Volume: 50
Pages: 321-330
Author Address: