4th International Conference on Medical Imaging with Deep Learning Jul 07, 2021 - Jul 09, 2021 — Virtual Meeting (online)
Medical Image Understanding and Analysis Conference 2021 Jul 12, 2021 - Jul 14, 2021 — Virtual Meeting (online)
Medical Imaging Convention [rescheduled] Sep 15, 2021 - Sep 16, 2021 — National Exhibition Centre, Birmingham, England
2021 SINAPSE ASM Sep 16, 2021 - Sep 17, 2021 — Technology & Innovation Centre, University of Strathclyde, 99 George Street, Glasgow
Total Body PET 2021 conference [rescheduled] Sep 22, 2021 - Sep 24, 2021 — Virtual Meeting (online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Choice of spectroscopic lineshape model affects metabolite peak areas and area ratios

Author(s): I. Marshall, S. D. Bruce, J. Higinbotham, A. MacLullich, J. M. Wardlaw, K. J. Ferguson, J. Seckl

Abstract:
The use of Lorentzian model lineshapes leads to systematic errors in the quantification of in vivo H-1 NMR spectra, Experimental lineshapes are better modeled by the Voigt (mixed Lorentzian-Gaussian) function, leading to more accurate fits (reduced chi(2)). In this work, results from a group of 41 subjects are presented. It is shown that not only are the estimated metabolite peak areas affected by the choice of lineshape model, but so too are the metabolite ratios. For example, the NAA/choline ratio was 1.92 +/- 0.06 (mean +/- standard error) using the Lorentzian lineshape model and 1.85 +/- 0.05 using the Voigt lineshape model. The corresponding figures for NAA/creatine were 2.32 +/- 0.06 and 2.10 +/- 0.05 respectively, which are significantly different for the two lineshape models, An explanation of this previously unreported effect is given, This finding clearly has serious implications for the methodology and reporting of spectroscopic studies. (C) 2000 Wiley-Liss, Inc.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0740-3194
Publication Year: 2000
Periodical: Magnetic Resonance in Medicine
Periodical Number: 4
Volume: 44
Pages: 646-649
Author Address: