Total Body PET 2021 conference [rescheduled] Sep 22, 2021 - Sep 24, 2021 — Virtual Meeting (online)
PET is Wonderful Annual Meeting 2021 Oct 26, 2021 12:00 AM — Virtual Meeting (online)
NRS Mental Health Network Annual Scientific Meeting 2021 Nov 02, 2021 09:00 AM - 05:00 PM — Royal College of Physicians, Edinburgh (and online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Comparison of the reproducibility of quantitative cardiac left ventricular assessments in healthy volunteers using different MRI scanners: a multicenter simulation

Author(s): S. J. Gandy, S. A. Waugh, R. S. Nicholas, H. J. Simpson, W. Milne, J. G. Houston

Abstract:
Purpose: To derive reproducibility assessments of ejection fraction (EF) and left ventricular mass (LVM) from shortaxis cardiac MR images acquired at single and multiple time-points on different 1.5T scanner models. Materials and Methods: Images of 15 healthy volunteers were acquired twice using a Magnetom Avanto scanner (Siemens, Erlangen, Germany) and once using a Signa Excite scanner (General Electric, Milwaukee, WI, USA) over four months, and analyzed using ARGUS and MASS Analysis+ software, respectively. Two physicists independently segmented the myocardial borders in order to derive intraand interobserver assessments of EF and LVM for single and multiple time-points on the same and different scanners. Results: For EF, the coefficient of repeatability (CoR) increased as different observers, multiple time-points, and different scanners were introduced. The CoR ranged from 2.8% (intraobserver measurements, single time-point, same scanner) to 10.0% (interobserver measurements, different timepoints, different scanners). For LVM, intraobserver CoR parameters were consistently smaller than interobserver values. The CoR ranged from 7.8 g (intraobserver measurements, single time-point, same scanner) to 39.5 g (interobserver measurements, different time-points, different scanners). Conclusion: Reproducible EF data can be obtained at single or multiple time-points. using different scanners. However, LUM is notably susceptible to interobserver variation, and this should be carefully considered if similar evaluations are planned as part of multicenter or longitudinal investigations.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 1053-1807
Publication Year: 2008
Periodical: Journal of Magnetic Resonance Imaging
Periodical Number: 2
Volume: 28
Pages: 359-365
Author Address: Gandy, SJ Ninewells Hosp, Natl Hlth Serv, Dept Med Phys, Dundee DD1 9SY, Scotland Ninewells Hosp, Natl Hlth Serv, Dept Med Phys, Dundee DD1 9SY, Scotland Ninewells Hosp, Natl Hlth Serv, Dept Clin Radiol, Dundee DD1 9SY, Scotland Univ Dundee, Sch Med, Natl Hlth Serv, Tayside Inst Cardiovasc Res, Dundee, Scotland