NRS Mental Health Network Annual Scientific Meeting 2021 Nov 02, 2021 09:00 AM - 05:00 PM — Royal College of Physicians, Edinburgh (and online)
SRS Autumn Meeting 2021 Nov 12, 2021 08:30 AM - 04:00 PM — Dundee

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Development of a Monte Carlo simulation for APO-based PET detectors using a continuous scintillating crystal

Author(s): P. Clowes, S. McCallum, A. Welch

Abstract:
We are currently developing a multilayer avalanche photodiode (APD)-based detector for use in positron emission tomography (PET), which utilizes thin continuous crystals. In this paper, we developed a Monte Carlo-based simulation to aid in the design of such detectors. We measured the performance of a detector comprising a single thin continuous crystal (3.1 mm x 9.5 mm, x 9.5 mm) of lutetium yttrium ortho-silicate (LYSO) and an APD array (4 x 4) elements; each element 1.6 mm(2) and on a 2.3 mm pitch. We showed that a spatial resolution of better than 2.12 mm is achievable throughout the crystal provided that we adopt a Statistics Based Positioning (SBP) Algorithm. We then used Monte Carlo simulation to model the behavior of the detector. The accuracy of the Monte Carlo simulation was verified by comparing measured and simulated parent datasets (PDS) for the SBP algorithm. These datasets consisted of data for point sources at 49 positions uniformly distributed over the detector area. We also calculated the noise in the detector circuit and verified this value by measurement. The noise value was included in the simulation. We show that the performance of the simulation closely matches the measured performance. The simulations were extended to investigate the effect of different noise levels on positioning accuracy. This paper showed that if modest improvements could be made in the circuit noise then positioning accuracy would be greatly improved. In summary, we have developed a model that can be used to simulate the performance of a variety of APD-based continuous crystal PET detectors.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0018-9499
Publication Year: 2006
Periodical: Ieee Transactions on Nuclear Science
Periodical Number: 5
Volume: 53
Pages: 2563-2569
Author Address: