PET is Wonderful Annual Meeting 2020 Oct 27, 2020 02:00 PM - 05:40 PM — Virtual Meeting (online)
Through the Looking Glass: Breaking Barriers in STEM Oct 28, 2020 12:00 PM - 03:30 PM — Virtual Meeting (online)
NRS Mental Health Network Annual Scientific Meeting 2020 Nov 04, 2020 09:00 AM - 05:30 PM — Virtual Meeting (online)
Scottish Radiological Society Annual General Meeting 2020 Nov 06, 2020 09:30 AM - 03:30 PM — Virtual Meeting (online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

On the use of the FLAIR technique to improve the correction of eddy current induced artefacts in MR diffusion tensor imaging

Author(s): M. E. Bastin

Abstract:
Eddy current induced geometric distortions can only be accurately corrected in brain diffusion-weighted echo-planar (DW-EP) images for b-values less than approximately 300 s mm(-2) using the iterative cross-correlation (ICC) algorithm. This is due to the difference in signal intensity of the cerebrospinal fluid (CSF) compartment in the diffusion-weighted and baseline T-2-weighted echo-planar (T2W-EP) images. At larger values of b, image misalignment artefacts can, however, be removed by directly correlating CSF-suppressed T2W-EP images with non-CSF-suppressed and CSF-suppressed DW-EP images. Separate phantom experiments can also be performed to provide eddy current calibration data. Here the ability of these methods to remove eddy current induced artefacts from DW-EP images collected in volunteer diffusion tensor imaging (DTI) experiments is investigated. Monte Carlo simulations show that in order for the ICC algorithm to produce accurate estimates of the eddy current induced distortions at b-values greater than 1000 s mm(-2), the degree of CSF suppression should be greater than approximately 80%. This condition is typically met for FLAIR inversion times between 0.5 and 0.8 of the spin-lattice relaxation time of CSF. In volunteer studies the most complete image realignment was provided by direct correlation of CSF-suppressed T2W-EP and DW-EP images acquired in the FLAIR DTI experiment. These results indicate that although calibration data obtained from brain or phantom images can significantly reduce eddy current induced distortions, the optimum image realignment achievable using post-processing methods is likely to be that obtained by direct image warping techniques. (C) 2001 Elsevier Science Inc. All rights reserved.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0730-725X
Publication Year: 2001
Periodical: Magnetic Resonance Imaging
Periodical Number: 7
Volume: 19
Pages: 937-950
Author Address: