iCAIRD, NHS GG&C and NVIDIA: AI in Healthcare Feb 25, 2021 09:00 AM - 12:15 PM — Virtual Meeting (online)
RiiSE21 Conference Apr 10, 2021 12:00 AM — Virtual Meeting (online)
Scottish Radiological Society Spring Meeting 2021 May 14, 2021 09:00 AM - 05:00 PM — Virtual Meeting (online)
2021 SINAPSE ASM Jun 17, 2021 - Jun 18, 2021 — Provisionally: Medical Sciences Building, University of St Andrews
Medical Imaging Convention [rescheduled] Sep 15, 2021 - Sep 16, 2021 — National Exhibition Centre, Birmingham, England

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

On the use of water phantom images to calibrate and correct eddy current induced artefacts in MR diffusion tensor imaging

Author(s): M. E. Bastin, P. A. Armitage

Abstract:
The accurate determination of absolute measures of diffusion anisotropy in vivo using single-shot, echo-planar imaging techniques requires the acquisition of a set of high signal-to-noise ratio, diffusion-weighted images that are free from eddy current induced image distortions. Such geometric distortions can be characterized and corrected in brain imaging data using magnification (M), translation (T), and shear (S) distortion parameters derived from separate water phantom calibration experiments. Here we examine the practicalities of using separate phantom calibration data to correct high b-value diffusion tensor imaging data by investigating the stability of these distortion parameters, and hence the eddy currents, with time. It is found that M, T, and S vary only slowly with time (i.e., on the order of weeks), so that calibration scans need not be performed after every patient examination. This not only minimises the scan time required to collect the calibration data, but also the computational time needed to characterize these eddy current induced distortions. Examples of how measurements of diffusion anisotropy are improved using this post-processing scheme are also presented. (C) 2000 Elsevier Science Inc. All rights reserved.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0730-725X
Publication Year: 2000
Periodical: Magnetic Resonance Imaging
Periodical Number: 6
Volume: 18
Pages: 681-687
Author Address: