PET is Wonderful Annual Meeting 2020 Oct 27, 2020 02:00 PM - 05:40 PM — Virtual Meeting (online)
Through the Looking Glass: Breaking Barriers in STEM Oct 28, 2020 12:00 PM - 03:30 PM — Virtual Meeting (online)
NRS Mental Health Network Annual Scientific Meeting 2020 Nov 04, 2020 09:00 AM - 05:30 PM — Virtual Meeting (online)
Scottish Radiological Society Annual General Meeting 2020 Nov 06, 2020 09:30 AM - 03:30 PM — Virtual Meeting (online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Safety of orthopedic implants in magnetic resonance imaging: An experimental verification

Author(s): R. Kumar, R. A. Lerski, S. Gandy, B. A. Clift, R. J. Abboud

Abstract:
Magnetic resonance imaging (MRI) is an indispensable tool for musculoskeletal imaging., The presence of metal, however, raises concerns. The potential risks are loosening and migration of the implant, heating of the metal with surrounding tissue, causing thermal damage, and artifactual distortion which compromise the diagnostic value of the procedure. The aim of this study was to test experimentally the nature and extent of the first two of these effects in orthopedic implants. The degree of ferromagnetism was evaluated by deflection studies at the portals of a 0.25 Tesla permanent magnet and 1.0 Tesla clinical MRI scanner. None of the orthopedic implants exhibited any attraction. External fixator clamps, however, showed significant ferromagnetism. The heating of implants by "worst-case" scenario imaging sequences was insignificant. Many contemporary nonferromagnetic orthopedic implants can be imaged safely. It is prudent, however, to perform ex vivo deflection studies on a duplicate implant to confirm MR compatibility. With external fixator devices exhibiting strong ferromagnetism, MRI should be avoided. With expanding indications for MRI, orthopedic implants are unlikely to limit the potential of this powerful. tool. (c) 2006 Orthopaedic Research Society.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 0736-0266
Publication Year: 2006
Periodical: Journal of Orthopaedic Research
Periodical Number: 9
Volume: 24
Pages: 1799-1802
Author Address: