PET is Wonderful Annual Meeting 2021 Oct 26, 2021 12:00 AM — Virtual Meeting (online)
NRS Mental Health Network Annual Scientific Meeting 2021 Nov 02, 2021 09:00 AM - 05:00 PM — Royal College of Physicians, Edinburgh (and online)

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Automated clarity assessment of retinal images using regionally based structural and statistical measures

Author(s): A. D. Fleming, S. Philip, K. A. Goatman, P. F. Sharp, J. A. Olson

Abstract:
An automated image analysis system for application in mass medical screening must assess the clarity of the images before analysing their content. This is the case in grading for diabetic retinopathy screening where the failure to assess clarity could result in retinal images of people with retinopathy being erroneously classed as normal. This paper compares methods of clarity assessment based on the degradation of visible structures and based on the deviation of image properties outside expected norms caused by clarity loss. Vessel visibility measures and statistical measures were determined at locations in the image which have high saliency and these were used to obtain an image clarity assessment using supervised classification. The usefulness of the measures as indicators of image clarity was assessed. Tests were performed on 987 disc-centred and macula-centred retinal photographs (347 with inadequate clarity) obtained from the English National Screening Programme. Images with inadequate clarity were detected with 92.6% sensitivity at 90% specificity. In a set of 2000 macula-centred images (200 with inadequate clarity) from the Scottish Screening Programme, inadequate clarity was detected with 96.7% sensitivity at 90% specificity. This study has shown that structural and statistical measures are equally useful for retinal image clarity assessment.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 1873-4030 (Electronic) 1350-4533 (Linking)
Publication Year: 2012
Periodical: Med Eng Phys
Periodical Number: 7
Volume: 34
Pages: 849-59
Author Address: University of Aberdeen, Aberdeen University and Grampian University Hospitals, Foresterhill, Aberdeen AB25 2ZD, United Kingdom.