Scottish Radiological Society Spring Meeting 2021 May 14, 2021 09:00 AM - 05:00 PM — Virtual Meeting (online)
9th Annual Scottish Radiotherapy Research Forum Jun 03, 2021 12:30 PM - 05:00 PM — Virtual Meeting (online)
Medical Imaging Convention [rescheduled] Sep 15, 2021 - Sep 16, 2021 — National Exhibition Centre, Birmingham, England
Total Body PET 2021 conference [rescheduled] Sep 25, 2021 - Sep 27, 2021 — McEwan Hall, University of Edinburgh

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Diffusion-weighted imaging in uterine artery embolisation: do findings correlate with contrast enhancement and volume reduction?

Author(s): G. Ananthakrishnan, G. Macnaught, L. Hinksman, H. Gilmour, K. P. Forbes, J. G. Moss

Abstract:
OBJECTIVES: The objective of this study was to determine the role of diffusion-weighted imaging (DWI) in uterine artery embolisation (UAE), and to assess the apparent diffusion coefficient (ADC) of the dominant fibroid and its relationship to contrast enhancement and fibroid volume reduction. METHODS: We carried out a retrospective study of 15 patients who underwent UAE. Calculations were performed at baseline and 6 months post-embolisation. Fibroid ADC (expressed in 10(-3) mm(2) s(-1)) was calculated using b=0 and b=1000 DWI values. Fibroid enhancement was compared with background myometrium by measuring signal-difference-to-noise ratio (SDNR). Fibroid volume was calculated using a prolate ellipse formula. RESULTS: There was a significant reduction (p<0.001) in fibroid ADC at 6 months (0.48; standard deviation, SD=0.26) as compared with baseline (1.01; SD=0.39). No significant change (p=0.07) was identified in 6-month myometrial ADC (1.09; SD=0.28) as compared with baseline (1.24; SD=0.20). Moderately strong and significant positive correlation was identified between baseline ADC and 6-month percentage volume reduction of the fibroid (correlation=0.66, p=0.007). No correlation was identified between SDNR and ADC at baseline or 6 months (r=0.01, p=0.97 and r=-0.13, p=0.64, respectively) or SDNR and percentage volume reduction at 6 months (correlation r=0.18, p=0.51). CONCLUSION: Baseline ADC of dominant fibroids shows a moderately strong correlation with subsequent volume reduction at 6 months following UAE. No correlation was identified between ADC values and contrast enhancement on the baseline or 6-month scans. Further prospective evaluation is needed before DWI can be utilised in clinical practice. Advances in knowledge DWI imaging may provide additional information about UAE and possibly help to predict uterine volume reduction.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 1748-880X (Electronic)0007-1285 (Linking)
Publication Year: 2012
Periodical: Br J Radiol
Periodical Number: 1019
Volume: 85
Pages: e1046-50
Author Address: Gartnavel General Hospital, Glasgow, UK.