Scottish Radiological Society Spring Meeting 2021 May 14, 2021 09:00 AM - 05:00 PM — Virtual Meeting (online)
9th Annual Scottish Radiotherapy Research Forum Jun 03, 2021 12:30 PM - 05:00 PM — Virtual Meeting (online)
Medical Imaging Convention [rescheduled] Sep 15, 2021 - Sep 16, 2021 — National Exhibition Centre, Birmingham, England
Total Body PET 2021 conference [rescheduled] Sep 25, 2021 - Sep 27, 2021 — McEwan Hall, University of Edinburgh

eLearning

SINAPSE experts from around Scotland have developed ten online modules designed to explain medical imaging. They are freely available and are intended for non-specialists.


Edinburgh Imaging Academy at the University of Edinburgh offers the following online programmes through a virtual learning environment:

Neuroimaging for Research MSc/Dip/Cert

Imaging MSc/Dip/Cert

PET-MR Principles & Applications Cert

Applied Medical Image Analysis Cert

Online Short Courses

Reliability of MRSI brain temperature mapping at 1.5 and 3 T

Author(s): M. J. Thrippleton, J. Parikh, B. A. Harris, S. J. Hammer, S. I. Semple, P. J. Andrews, J. M. Wardlaw, I. Marshall

Abstract:
MRSI permits the non-invasive mapping of brain temperature in vivo, but information regarding its reliability is lacking. We obtained MRSI data from 31 healthy male volunteers [age range, 22-40 years; mean +/- standard deviation (SD), 30.5 +/- 5.0 years]. Eleven subjects (age range, 23-40 years; mean +/- SD, 30.5 +/- 5.2 years) were invited to receive four point-resolved spectroscopy MRSI scans on each of 3 days in both 1.5-T (TR/TE = 1000/144 ms) and 3-T (TR/TE = 1700/144 ms) clinical scanners; a further 20 subjects (age range, 22-40 years; mean +/- SD, 30.5 +/- 4.9 years) were scanned on a single occasion at 3 T. Data were fitted in the time domain to determine the water-N-acetylaspartate chemical shift difference, from which the temperature was estimated. Temperature data were analysed using a linear mixed effects model to determine variance components and systematic temperature changes during the scanning sessions. To characterise the effects of instrumental drift on apparent MRSI brain temperature, a temperature-controlled phantom was constructed and scanned on multiple occasions. Components of apparent in vivo temperature variability at 1.5 T/3 T caused by inter-subject (0.18/0.17 degrees C), inter-session (0.18/0.15 degrees C) and within-session (0.36/0.14 degrees C) effects, as well as voxel-to-voxel variation (0.59/0.54 degrees C), were determined. There was a brain cooling effect during in vivo MRSI of 0.10 degrees C [95% confidence interval (CI): -0.110, -0.094 degrees C; p < 0.001] and 0.051 degrees C (95% CI: -0.054, -0.048 degrees C; p < 0.001) per scan at 1.5 T and 3 T, respectively, whereas phantom measurements revealed minimal drift in apparent MRSI temperature relative to fibre-optic temperature measurements. The mean brain temperature at 3 T was weakly associated with aural (R = 0.55, p = 0.002) and oral (R = 0.62, p < 0.001) measurements of head temperature. In conclusion, the variability associated with MRSI brain temperature mapping was quantified. Repeatability was somewhat higher at 3 T than at 1.5 T, although subtle spatial and temporal variations in apparent temperature were demonstrated at both field strengths. Such data should assist in the efficient design of future clinical studies. (c) 2013 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.

Full version: Available here

Click the link to go to an external website with the full version of the paper


ISBN: 1099-1492 (Electronic)0952-3480 (Linking)
Publication Year: 2013
Periodical: NMR Biomed
Periodical Number:
Volume:
Pages:
Author Address: Brain Research Imaging Centre, Centre for Clinical Brain Sciences, University of Edinburgh, Edinburgh, UK.